Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
Horm Res Paediatr ; 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38705144

RESUMEN

INTRODUCTION: Stimulated copeptin may provide an alternative to water deprivation testing (WDT) in the evaluation of polyuria-polydipsia syndrome (PPS). Though best studied, arginine stimulation alone produces a modest copeptin response in children. We investigated the effectiveness of the arginine + LevoDopa/Carbidopa stimulation test (ALD-ST) for copeptin. METHODS: 47 healthy short children (controls), 10 children with primary polydipsia and 10 children with AVP deficiency received arginine hydrochloride (500 mg/Kg intravenously over 30 minutes) and Levodopa/carbidopa (10:1 ratio; 175 mg of L-Dopa/m2 BSA) orally. Serum copeptin was measured at 0 60, 90 and 120 minutes. RESULTS: In controls, ALD-ST increased copeptin from a median of 7.0 pMol/L (IQR 5.0-10.0) to a peak of 44.0 pMol/L (IQR 21.4-181.0) between 60-120 minutes (p<0.001). Copeptin peak was higher in subjects who experienced nausea or vomiting (57%) than in those who did not (131.0 pMol/L [IQR 42.5-193.8] vs 22.7 pMol/L [IQR 16.0-33.7], p<0.001). While subjects with primary polydipsia had similar baseline (8.5 pMol/L [IQR 8.0-11.0]) and stimulated (125.2 pMol/L [IQR 87.6-174.0]) copeptin levels as controls, subjects with AVP deficiency had lower baseline (2.5 pMol/L [IQR 2.0-3.1]) and peak levels (4.6 pMol/L [IQR 2.4-6.0]). A peak copeptin of ≥9.3 pMol/L best predicted absence of complete or partial AVP deficiency with a sensitivity of 100% and specificity of 80%. CONCLUSIONS: ALD-ST induced a robust peak copeptin in healthy short children and children with primary polydipsia. Nausea/vomiting, a side effect of ALD-ST, amplified the copeptin response. The ALD-ST may be a suitable initial screening test in children with PPS.

2.
Front Mol Biosci ; 11: 1365760, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38638689

RESUMEN

The lungs are a key organ in the respiratory system. They are regulated by a complex network of nerves that control their development, structure, function, and response to various pathological stimuli. Accumulating evidence suggests the involvement of a neural mechanism in different pathophysiological conditions in the lungs and the development and progression of common respiratory diseases. Lung diseases are the chief source of death globally. For instance, lung cancer is the second most commonly diagnosed malignancy, after prostate cancer in men and breast cancer in women, and is the most lethal cancer worldwide. However, although airway nerves are accepted as a mechanistically and therapeutically important feature that demands appropriate emphasizing in the context of many respiratory diseases, significantly less is known about the role of the neuroglial cells in lung physiology and pathophysiology, including lung cancer. New data have uncovered some cellular and molecular mechanisms of how Schwann cells, as fundamental components of the peripheral nervous system, may regulate lung cancer cells' survival, spreading, and invasiveness in vitro and in vivo. Schwann cells control the formation and maintenance of the lung cancer microenvironment and support metastasis formation. It was also reported that the number of lung cancer-associated Schwann cells correlates with patients' survival. Different factors secreted by Schwann cells, including microRNA, are known to sharpen the lung cancer environment by regulating the tumor-neuro-immune axis. Further clinical and experimental studies are required to elucidate the detailed role of Schwann cells in creating and maintaining pulmonary tumor-neuro-immune axis, which will advance our understanding of the pathogenesis of lung cancer and may inform therapeutic hypotheses aiming neoplasms and metastases in the lung.

3.
Immunotargets Ther ; 13: 215-234, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38686351

RESUMEN

Autoantibodies are a common mark of autoimmune reaction and their identification in the patients' serum, cerebrospinal fluid, or tissues is generally believed to represent diagnostic or prognostic biomarkers of autoimmune diseases or autoinflammatory conditions. Traditionally, autoantibody testing is an important part of the clinical examination of suspected patients, and in the absence of reliable T cell tests, characterization of autoantibody responses might be suitable in finding causes of specific autoimmune responses, their strength, and sometimes commencement of autoimmune disease. Autoantibodies are also useful for prognostic stratification in clinically diverse groups of patients if checked repeatedly. Antibody discoveries are continuing, with important consequences for verifying autoimmune mechanisms, diagnostic feasibility, and clinical management. Adding newly identified autoantibody-autoantigen pairs to common clinical laboratory panels should help upgrade and harmonize the identification of systemic autoimmune rheumatic disorders and other autoimmune conditions. Herein, we aim to summarize our current knowledge of uncommon and novel autoantibodies in the context of discussing their validation, diagnostic practicability, and clinical relevance. The regular updates within the field are important and well justified.

6.
JAMA Netw Open ; 6(10): e2339355, 2023 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-37874566

RESUMEN

Importance: SARS-CoV-2 surveillance studies in US child care centers (CCCs) in the post-COVID-19 vaccine era are needed to provide information on incidence and transmission in this setting. Objective: To characterize SARS-CoV-2 incidence and transmission in children attending CCCs (students) and their child care providers (CCPs) and household contacts. Design, Setting, and Participants: This prospective surveillance cohort study was conducted from April 22, 2021, through March 31, 2022, and included 11 CCCs in 2 cities. A subset (surveillance group) of CCPs and students participated in active surveillance (weekly reverse transcription-polymerase chain reaction [RT-PCR] swabs, symptom diaries, and optional baseline and end-of-study SARS-CoV-2 serologic testing), as well as all household contacts of surveillance students. Child care center directors reported weekly deidentified self-reported COVID-19 cases from all CCPs and students (self-report group). Exposure: SARS-CoV-2 infection in CCC students. Main Outcomes and Measures: SARS-CoV-2 incidence, secondary attack rates, and transmission patterns were determined from diary entries, self-reports to CCC directors, and case logs. Incidence rate ratios were measured using Poisson regression clustering on centers with a random intercept and unstructured matrix. Results: From a total population of 1154 students and 402 CCPs who self-reported cases to center directors, 83 students (7.2%; mean [SD] age, 3.86 [1.64] years; 55 male [66%]), their 134 household contacts (118 adults [mean (SD) age, 38.39 (5.07) years; 62 female (53%)], 16 children [mean (SD) age, 4.73 (3.37) years; 8 female (50%)]), and 21 CCPs (5.2%; mean [SD] age, 38.5 [12.9] years; 18 female [86%]) participated in weekly active surveillance. There were 154 student cases (13%) and 87 CCP cases (22%), as defined by positive SARS-CoV-2 RT-PCR or home antigen results. Surveillance students had a higher incidence rate than self-report students (incidence rate ratio, 1.9; 95% CI, 1.1-3.3; P = .01). Students were more likely than CCPs to have asymptomatic infection (34% vs 8%, P < .001). The CCC secondary attack rate was 2.7% to 3.0%, with the upper range representing possible but not definite secondary cases. Whether the index case was a student or CCP, transmission within the CCC was not significantly different. Household cumulative incidence was 20.5%, with no significant difference in incidence rate ratio between adults and children. Household secondary attack rates were 50% for children and 67% for adults. Of 30 household cases, only 5 (17%) represented secondary infections caused by 3 students who acquired SARS-CoV-2 from their CCC. Pre- and poststudy seroprevalence rates were 3% and 22%, respectively, with 90% concordance with antigen or RT-PCR results. Conclusions and Relevance: In this study of SARS-CoV-2 incidence and transmission in CCCs and students' households, transmission within CCCs and from children infected at CCCs into households was low. These findings suggest that current testing and exclusion recommendations for SARS-CoV-2 in CCCs should be aligned with those for other respiratory viruses with similar morbidity and greater transmission to households.


Asunto(s)
COVID-19 , SARS-CoV-2 , Adulto , Niño , Masculino , Humanos , Femenino , Preescolar , COVID-19/epidemiología , COVID-19/prevención & control , Incidencia , Vacunas contra la COVID-19 , Estudios de Cohortes , Estudios Prospectivos , Cuidado del Niño , Estudios Seroepidemiológicos
7.
Clin Chem Lab Med ; 61(12): 2094-2101, 2023 11 27.
Artículo en Inglés | MEDLINE | ID: mdl-37327359

RESUMEN

OBJECTIVES: The trueness and precision of clinical laboratory results are ensured through total quality management systems (TQM), which primarily include internal quality control (IQC) practices. However, quality practices vary globally. To understand the current global state of IQC practice and IQC management in relation to TQM the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Global Laboratory Quality (TF-GLQ) conducted a survey of IFCC member countries on IQC practices and management. METHODS: The survey included 16 questions regarding IQC and laboratory TQM practices and was distributed to IFCC full and affiliate member countries (n=110). A total of 46 (41.8 %) responses were received from all regions except North America. RESULTS: Of the responding countries, 78.3 % (n=36) had legislative regulations or accreditation requirements governing medical laboratory quality standards. However, implementation was not mandatory in 46.7 % (n=21) of responding countries. IQC practices varied considerably with 57.1 % (n=28) of respondents indicating that they run 2 levels of IQC, 66.7 % (n=24) indicating they run IQC every 24 h and 66.7 % (n=28) using assay manufacturer IQC material sources. Only 29.3 % (n=12) of respondents indicated that every medical laboratory in their country has written IQC policies and procedures. By contrast, 97.6 % (n=40) of responding countries indicated they take corrective action and result remediation in the event of IQC failure. CONCLUSIONS: The variability in TQM and IQC practices highlights the need for more formal programs and education to standardize and improve TQM in medical laboratories.


Asunto(s)
Laboratorios , Gestión de la Calidad Total , Humanos , Control de Calidad , Encuestas y Cuestionarios
8.
J Pathol Inform ; 14: 100300, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36880026

RESUMEN

Diagnostic advances have not kept pace with the expansion of Lyme disease caused by Borrelia burgdorferi and transmitted by ticks. Lyme disease clinical manifestations can overlap with many other diagnoses making Lyme disease a critical part of many differential diagnoses in endemic areas. Current diagnostic blood tests rely on a 2-tiered algorithm for which the second step is either a time-consuming western blot or a whole cell lysate immunoassay. Neither of these second step tests allow for rapid results of this critical rule out test. We hypothesized that using western blot confirmation information, we could create computational models to propose recombinant second-tier tests that would allow for more rapid, automated, and specific testing algorithms. We propose here a framework for assessing retrospective data to determine putative recombinant assay components. A retrospective pediatric cohort of 2755 samples submitted for Lyme disease screening was assessed using support vector machine learning algorithms to optimize tier 1 diagnostic thresholds for the Vidas IgG II assay and determine optimal tier 2 components for both a positive and negative confirmation test. In cases where the tier 1 screen was negative, but clinical suspicion was high, we found that 1 protein (L58) could be used to reduce false-negative results. For second-tier testing of screen positive cases, we found that 6 proteins could be used to reduce false-positive results (L18, L39M, L39, L41, L45, and L58) with a final machine learning classifier or 2 proteins using a final rules-based approach (L41, L18). This led to an overall accuracy of 92.36% for the proposed algorithm without a final machine learning classifier and 92.12% with integration of the machine learning classifier in the final algorithm when compared to the IgG western blot as the gold-standard. Use of this framework across multiple assays and institutions will allow for a data-driven approach to assay development to provide laboratories and patients with the improvements in turnaround time needed for this testing.

9.
Clin Chem Lab Med ; 61(8): 1404-1410, 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-36779362

RESUMEN

OBJECTIVES: Clinical laboratory results are required for critical medical decisions, underscoring the importance of quality results. As part of total quality management, external quality assessment (EQA) is a vital component to ensure laboratory accuracy. The goal of this survey was to evaluate the current status of global laboratory quality systems and assess the need for implementation, expansion, or harmonization of EQA programs (EQAP) for Clinical Chemistry and Laboratory Medicine. METHODS: The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Global Laboratory Quality (TF-GLQ) conducted a survey of IFCC full and affiliate members (n=110) on laboratory quality practice. A total of 41 (37.3%) countries representing all IFCC regions except North America provided responses about EQA availability and practices. RESULTS: All 41 countries perform EQA, 38 reported that their laboratories had EQA policies and procedures, and 39 further act/evaluate unacceptable EQA results. 39 countries indicated they have international and/or national EQAP and 30 use alternative performance assessments. EQA frequency varied among countries. Generally, an EQAP provided the EQA materials (40/41) with four countries indicating that they did not have an EQAP in their country. CONCLUSIONS: Globally, most laboratories participate in an EQAP and have defined quality procedures for EQA. There remain gaps in EQA material availability and implementation of EQA as a part of a total laboratory quality system. This survey highlights the need for education, training, and harmonization and will guide efforts of the IFCC TF-GLQ in identifying areas for enhancing global laboratory quality practices.


Asunto(s)
Química Clínica , Laboratorios , Humanos , Encuestas y Cuestionarios , Gestión de la Calidad Total , Garantía de la Calidad de Atención de Salud
10.
Horm Res Paediatr ; 96(4): 395-403, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36513057

RESUMEN

INTRODUCTION: Copeptin, co-secreted with arginine vasopressin, is regulated by osmotic and volume stimuli but also responds to intravenous arginine and insulin-induced hypoglycemia. The serum copeptin response to the latter agents has been studied in adults but only to a limited extent in children. The objective of this study was to describe the copeptin response to combined arginine and insulin in children with normal posterior pituitary function. METHODS: We conducted a prospective, single-arm assessment of serum copeptin concentrations in children (age 7-16 years, n = 38) undergoing growth hormone stimulation testing with an arginine-insulin tolerance test (AITT) for short stature or growth deceleration in a tertiary referral center. After overnight fasting, arginine (500 mg/kg) was administered between 0 and 30 min intravenously (IV) followed by insulin (0.1 units/kg IV) at 60 min. Copeptin serum concentrations were measured at baseline (0 min), at the post-arginine peak (60 min), and at the post-insulin peak (90 min; 30 min post-insulin), respectively. The main outcome was the peak copeptin concentration. RESULTS: Mean ± SD copeptin concentrations increased from 9.9 ± 5.0 pmol/L at 0 min to 13.2 ± 5.8 pmol/L at 60 min (p < 0.0001 vs. 0 min) and 27.7 ± 14.2 pmol/L at 90 min (p < 0.0001 vs. 0 and 60 min). There was no significant correlation between copeptin concentrations and age, BMI, pubertal status, cortisol, growth hormone, or glucose concentrations. DISCUSSION/CONCLUSION: Arginine and insulin appear to have an additive and consistent effect resulting in significant stimulation of copeptin secretion in children. The AITT may be a useful tool to evaluate for normal posterior pituitary function in this age-group, with potential implications for the evaluation of polyuria-polydipsia syndrome.


Asunto(s)
Hipoglucemia , Insulina , Adolescente , Niño , Humanos , Arginina , Hormona del Crecimiento , Estudios Prospectivos
11.
Am J Clin Pathol ; 159(1): 10-13, 2023 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-36469049

RESUMEN

OBJECTIVES: There is concern that the anti-severe acute respiratory syndrome coronavirus 2 therapeutic monoclonal antibodies, used as preexposure prophylaxis in patients with multiple myeloma, may appear as a detectable monoclonal protein by electrophoretic methods, resulting in misinterpretation or inability to measure therapeutic responses in some patients. In this pilot study, we characterize the effect of tixagevimab plus cilgavimab (Evusheld; T + C) on interpretation of serum protein electrophoresis (SPE), immunofixation electrophoresis (IFE), and serum free light chain (sFLC) assays. METHODS: We performed spiking experiments with T + C at serum maximum concentration following a 300-mg dose (1× Cmax) and at 10 times the concentration of Cmax (10× Cmax) with pooled serum samples. SPE and IFE technical procedures were performed on the SPIFE 3000, and sFLC and immunoglobulin G1 (IgG1) subtype quantitation was performed on the Optilite. RESULTS: T + C-associated interference was not visible as an M-spike in normogammaglobulinemic pooled samples. Hypogammaglobulemic pooled samples at 10× Cmax demonstrated an M-spike in SPE and immunoglobulin Gκ pattern in IFE. No increases were noted in the results of sFLC or IgG1 levels. CONCLUSIONS: This study indicates that T + C at pharmacologic Cmax is unlikely to interfere with SPE, IFE, sFLC, or IgG1 analyses when spiked into patient serum samples, but further evaluation of recently injected patients may be warranted.


Asunto(s)
COVID-19 , Humanos , Proyectos Piloto , Cadenas Ligeras de Inmunoglobulina , Electroforesis , Anticuerpos Monoclonales/uso terapéutico , Inmunoglobulina G
12.
Lab Med ; 54(2): e54-e57, 2023 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-36065160

RESUMEN

OBJECTIVE: Independent assessment of SARS-CoV-2 antigen (COV2Ag) tests remains important as varying performance between assays is common. We assessed the performance of a new high-throughput COV2Ag test compared to SARS-CoV-2 nucleic acid amplification tests (NAAT). METHODS: A total of 347 nasopharyngeal samples collected from January to October 2021 were assessed by NAAT as part of standard-of-care testing (CDC LDT or GeneXpert System, Cepheid) and COV2Ag using the ADVIA Centaur CoV2Ag assay (Siemens Healthineers). RESULTS: Among NAAT positive specimens we found 82.4% agreement and in NAAT negative specimens we found 97.3% agreement (overall agreement 85.6%). In symptomatic persons, COV2Ag agreed with NAAT 90.0% (n = 291), and in asymptomatic persons, 62.5% (n = 56). Agreement between positive NAAT and COV2Ag increased at lower cycle threshold (Ct) values. CONCLUSION: The COV2Ag assay exceeded the World Health Organization minimum performance requirements of ≥ 80% sensitivity and ≥ 97% specificity. The COV2Ag assay is helpful for large scale screening efforts due to high-throughput and reduced wait times.


Asunto(s)
COVID-19 , Ácidos Nucleicos , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Prueba Serológica para COVID-19 , Técnicas de Amplificación de Ácido Nucleico
15.
Clin Biochem ; 109-110: 17-22, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36075469

RESUMEN

INTRODUCTION: Accurate diagnosis of viral meningoencephalitis (VMe) and identification of the etiologic agent has clinical importance and large serology panels are available to aid in the detection of several viral pathogens. However, such panels are often send-out testing, with prolonged time to results, thus impacting the actionability of test results. We hypothesized these panels may not contribute to patient care and lack clinical utility. METHODS: A retrospective review of all VMe CSF serology panels ordered at one pediatric (n = 53; 2017-2019) and two adult (n = 200; 2019-2020) tertiary care hospitals was performed to assess test clinical utility. Panels included serology for: Adenovirus, coxsackie and echoviruses, influenza, measles, lymphocytic choriomeningitis virus, herpes simplex virus, mumps, varicella zoster, encephalitis viruses. Clinical data collected included diagnostic test results, symptoms, comorbidities, and interventions. RESULTS: In 129/200 (64.5 %) of adult cases and 37/53 (69.8 %) of pediatric cases CSF had a WBC less than 5 cells/mm2. In total, 127 (63.5 %, 127/200) adult panels had at least one positive target with 49 panels having more than one positive (38.6 %, 49/127). In 99.5 % of adult and 100 % of pediatric cases there was no change to decisions regarding starting, discontinuing, continuing, or changing antimicrobial therapy based on panel results. In no cases were potentially immunosuppressive therapies like steroid or IVIG administration delayed while awaiting the results of the panel. CONCLUSIONS: While all patients presented with neurologic symptoms, poor pre-screening for CNS inflammation using CSF WBC analysis likely contributed to poor clinical utility of the VMe panels. Large CSF serologic panels for VMe did not contribute to or add value to clinical decision making in our cohort.


Asunto(s)
Meningoencefalitis , Adulto , Niño , Humanos , Meningoencefalitis/diagnóstico , Estudios Retrospectivos
16.
J Appl Lab Med ; 7(6): 1379-1387, 2022 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-35993812

RESUMEN

BACKGROUND: Therapeutic monoclonal antibodies can be a source of assay interference in clinical serum protein electrophoresis (SPEP) and immunofixation electrophoresis (IFE), producing monoclonal bands that can be misinterpreted as a monoclonal gammopathy related to a B-cell or plasma cell neoplasm. The extent to which new anti-COVID-19 monoclonal antibodies produce this interference is unknown. METHODS: Casirivimab plus imdevimab, sotrovimab, and bamlanivimab plus etesevimab were spiked into patient serum samples to evaluate for SPEP/IFE interference, to characterize the position of therapy-derived bands relative to a reference band (either combined beta band or beta 1 band, depending on instrument platform), and to confirm heavy and light chain utilization of each medication. Serum samples from patients who had recently received casirivimab plus imdevimab or sotrovimab were also evaluated for comparison. RESULTS: When spiked into serum samples, all tested anti-COVID-19 monoclonal antibodies generated interference in SPEP/IFE. Importantly, the patterns of interference differed between spiked serum samples and serum from patients who had recently received casirivimab plus imdevimab or sotrovimab. CONCLUSIONS: Imdevimab can be added to the growing list of therapeutic monoclonal antibodies that produce sustained interference in SPEP/IFE. Although casirivimab and sotrovimab also produce assay interference in vitro, these antibodies are not reliably detected in serum from recently infused patients. The value of relative band position in recognizing bands that may represent therapeutic monoclonal antibodies is also emphasized. Clinicians and laboratorians should consider therapeutic monoclonal antibody interference in diagnostic SPEP/IFE and review a patient's medication list when new or transient monoclonal bands are identified.


Asunto(s)
Anticuerpos Monoclonales , Tratamiento Farmacológico de COVID-19 , COVID-19 , Humanos , Electroforesis , COVID-19/diagnóstico
17.
Diagn Pathol ; 17(1): 63, 2022 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-35932039

RESUMEN

BACKGROUND: Mu heavy chain disease is a rare lymphoid neoplasm characterized by vacuolated bone marrow plasma cells and secretion of defective mu immunoglobulin heavy chains. The biological basis of mu heavy chain disease is poorly understood. CASE PRESENTATION: We report a case of mu heavy chain disease with MYD88 L265P mutation and deletion of 6q, genetic aberrations that are both strongly associated with lymphoplasmacytic lymphoma/Waldenström macroglobulinemia. Identification of the truncated mu immunoglobulin was facilitated by mass spectrometric analysis of the patient's serum. CONCLUSIONS: Mu heavy chain disease has been described as similar to chronic lymphocytic leukemia; however, the frequency of lymphocytosis in mu heavy chain disease has not been previously reported. We reviewed all previously published mu heavy chain disease reports and found that lymphocytosis is uncommon in the entity. This finding, along with the emerging genetic feature of recurrent MYD88 mutation in mu heavy chain disease, argues that at least a significant subset of cases are more similar to lymphoplasmacytic lymphoma than to chronic lymphocytic leukemia.


Asunto(s)
Enfermedad de las Cadenas Pesadas , Leucemia Linfocítica Crónica de Células B , Linfocitosis , Linfoma , Macroglobulinemia de Waldenström , Humanos , Leucemia Linfocítica Crónica de Células B/diagnóstico , Leucemia Linfocítica Crónica de Células B/genética , Mutación , Factor 88 de Diferenciación Mieloide/genética , Macroglobulinemia de Waldenström/diagnóstico , Macroglobulinemia de Waldenström/genética , Macroglobulinemia de Waldenström/patología
18.
Clin Chem Lab Med ; 60(6): 859-866, 2022 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-35397198

RESUMEN

OBJECTIVES: Ventilator management in prehospital settings using end-tidal CO2 can lead to inappropriate ventilation in the absence of point of care blood gas (POCBG) measurements. Implementation of POCBG testing in helicopter Emergency Medical Services (HEMS) is limited in part because of concern for preanalytical and analytical errors due to altitude, vibration, and other associated environmental factors and due to insufficient documentation of implementation challenges. METHODS: We performed accuracy and precision verification studies using standard materials tested pre-, in-, and post-flight (n=10) in a large HEMS agency. Quality assurance error log data were extracted and summarized for common POCBG errors during the first 31 months of use and air medical transport personnel were surveyed regarding POCBG use (n=63). RESULTS: No clinically significant differences were found between pre-, in-, and post-flight blood gas measurements. Error log data demonstrated a reduction in device errors over time. Survey participants found troubleshooting device errors and learning new clinical processes to be the largest barriers to implementation. Continued challenges for participants coincided with error log data including temperature and sampling difficulties. Survey participants indicated that POCBG testing improved patient management. CONCLUSIONS: POCBG testing does not appear to be compromised by the HEMS environment. Temperature excursions can be reduced by use of insulated transport bags with heating and cooling packs. Availability of POCBG results in air medical transport appeared to improve ventilator management, increase recognition of ventilation-perfusion mismatch, and improve patient tolerance of ventilation.


Asunto(s)
Ambulancias Aéreas , Servicios Médicos de Urgencia , Análisis de los Gases de la Sangre , Servicios Médicos de Urgencia/métodos , Humanos , Sistemas de Atención de Punto , Pruebas en el Punto de Atención , Estudios Retrospectivos
19.
Am J Clin Pathol ; 158(2): 162-166, 2022 08 04.
Artículo en Inglés | MEDLINE | ID: mdl-35353142

RESUMEN

OBJECTIVES: Acute viral infections and some vaccines have been shown to increase false positivity in serologic assays. We assessed if the messenger RNA coronavirus disease 2019 (COVID-19) vaccines could cause false reactivity in common serologic assays in a pilot longitudinal cohort. METHODS: Thirty-eight participants with sera available prevaccination, 2 weeks after each vaccine dose, and monthly thereafter for up to 5 months were tested for common infectious disease serologies and antiphospholipid syndrome (APS) serology markers on the BioPlex 2200, Sure-Vue rapid plasma reagin (RPR), and Macro-Vue RPR. Twenty-two participants received the Moderna vaccine and 16 received the Pfizer vaccine. RESULTS: Most assays had no change in reactivity over the course of the sample draws, including APS markers. Epstein-Barr virus immunoglobulin G (IgG), measles IgG, and rubella immunoglobulin M all had possible false reactivity in one to two participants. RPR tests demonstrated false reactivity, with baseline nonreactive participant samples becoming reactive following vaccination. There were more false reactive participants (7/38) in the BioPlex RPR than in the Sure-Vue (2/38) and Macro-Vue (1/38) tests. All falsely reactive RPR tests were in participants who received the Moderna vaccine. CONCLUSIONS: Serologic assays with results that do not fit the clinical picture following COVID-19 vaccination should be repeated. Effects of false reactivity can last more than 5 months in some assays. In particular, RPR is susceptible to false reactivity, and there is variability among assays. Larger longitudinal studies are needed to determine the incidence and window of false reactivity.


Asunto(s)
COVID-19 , Infecciones por Virus de Epstein-Barr , COVID-19/diagnóstico , COVID-19/prevención & control , Prueba de COVID-19 , Vacunas contra la COVID-19 , Herpesvirus Humano 4 , Humanos , Inmunoglobulina G , ARN Mensajero , Reaginas , Pruebas Serológicas , Serodiagnóstico de la Sífilis/métodos , Vacunas Sintéticas , Vacunas de ARNm
20.
J Appl Lab Med ; 7(4): 910-915, 2022 06 30.
Artículo en Inglés | MEDLINE | ID: mdl-35060610

RESUMEN

INTRODUCTION: The advent of therapeutic monoclonal antibodies (tmAbs) in treatment of multiple myeloma poses unique challenges for the clinical laboratory. These tmAbs may appear as a detectable monoclonal protein by electrophoretic methods resulting in misinterpretation or inability to measure therapeutic responses in some patients, and there are currently limited techniques for identifying interference. In this study we performed a preliminary assessment of the SPIFE anti-daratumumab (SPIFE anti-Dara) reagent to determine whether it would be a feasible aid in resolving the interference of tmAbs with serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE). METHODS: We performed a pilot study with 20 serum samples and clinical correlates. All samples had a characteristic daratumumab electrophoretic pattern (cathodal IgG/κ). A pre-electrophoretic sample treatment was performed with SPIFE anti-Dara. The reagent is a derivatized anti-Dara that forms multiple antibody/daratumumab complexes. SPE and IFE technical procedures were performed on Helena SPIFE 3000 according to the manufacturer instructions. RESULTS: Of the 20 patients, 14 patients were identified to be on daratumumab therapy. In 14/14 of cases, the daratumumab interference was successfully removed both from SPE and IFE assays. Disease associated M-protein was still visible after pretreatment, and quantification of M-protein may be possible with the use of SPIFE anti-Dara procedure. DISCUSSION: SPIFE anti-Dara is a promising method to remove the interference of therapeutic monoclonal antibody daratumumab with SPE and IFE results in clinical laboratories and warrants further assessment.


Asunto(s)
Anticuerpos Monoclonales , Mieloma Múltiple , Electroforesis , Humanos , Inmunoelectroforesis , Mieloma Múltiple/diagnóstico , Mieloma Múltiple/tratamiento farmacológico , Proyectos Piloto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...